Engineering

Precision Bearings Application Case Study (1)

1. Background

Bearing Type:7008C/7006C

Spindle Type:Spindle of honing machine

Bearing Arrangement:DB/DB (<> / <>)

Rotating Speed:6000 RPM

Phenomenon:Temp. rise became over high during running-in test in factory.

2. Investigation and Research

Before

Directly operated the spindle at 6000RPM after bearing replacement

7008C side temp. rise went up to 18℃, as shown in fig. 1.

Fig. 1 7008C side temp. rise

 

 

After

Increase the rotating speed by stages till 6000RPM

7008C side temp. rise was lowered to 4℃, as shown in fig 2.

Fig. 2 7008C side temp. rise

3. Conclusion

Operating spindles with newly replaced bearings may encounter abnormal temp. rise

phenomenon. Increasing the rotating speed by stages can spread out the grease within

bearing and increase bearing life.